I inherited a Vermont Casting woodstove for my cabin, the damper is stuck as in it got wet and now it won't move. Besides trying to work the rust free and if I can't do ya'll know if using an in pipe damper would be doable?


[Linked Image]

[Linked Image]

GB1

Joined: Oct 2008
Posts: 7,821
K
Campfire Outfitter
Offline
Campfire Outfitter
K
Joined: Oct 2008
Posts: 7,821
You really don't need a damper in the flue. Turning down the combustion air accomplishes the same thing.


�Nothing is so permanent as a temporary government program." -- Milton Friedman
Joined: Oct 2005
Posts: 79,321
B
Campfire Oracle
Offline
Campfire Oracle
B
Joined: Oct 2005
Posts: 79,321
I don't know,...but before you give up on it, soak it with this stuff a few times.

http://www.kanolabs.com/

Joined: Aug 2005
Posts: 7,262
Elf Offline OP
Campfire Tracker
OP Offline
Campfire Tracker
Joined: Aug 2005
Posts: 7,262
I turn that down how?

Joined: Dec 2009
Posts: 397
Campfire Member
Offline
Campfire Member
Joined: Dec 2009
Posts: 397
Do you have the door and the lid? The door should have a combustion air adjustible intake.


The Tail Goes Along With The Hide.

We should have picked our own cotton.
IC B2

Joined: Dec 2006
Posts: 52,680
Campfire Kahuna
Offline
Campfire Kahuna
Joined: Dec 2006
Posts: 52,680
Originally Posted by Bristoe
I don't know,...but before you give up on it, soak it with this stuff a few times.

http://www.kanolabs.com/


what Bristoe says~!


Liberalism is a mental disorder that leads to social disease.
Joined: Aug 2005
Posts: 7,262
Elf Offline OP
Campfire Tracker
OP Offline
Campfire Tracker
Joined: Aug 2005
Posts: 7,262
Originally Posted by Kojac
Do you have the door and the lid? The door should have a combustion air adjustible intake.


The doors are solid..as is the lid.

Joined: Sep 2003
Posts: 14,807
Campfire Outfitter
Offline
Campfire Outfitter
Joined: Sep 2003
Posts: 14,807
That looks like an older Resolute model. Call Vermont Castings and ask them for advice. If you have the front door and top lid then it may be worth bothering with. See what they say.

You don't need that damper on the back to work nor the air intake control.

Put a damper in the chimney above the stove and don't over load it.

http://vermontcastings.com/family/Stoves/Non-Catalytic/Resolute-Acclaim/



All guns should be locked up when not in use!
Joined: Sep 2009
Posts: 13,860
T
Campfire Outfitter
Offline
Campfire Outfitter
T
Joined: Sep 2009
Posts: 13,860
I have the smaller Intrepid stove, my damper handle is only for directing flue gas through the catalytic combuster, I never use it, it stays open. My air intake is simply a little flap over a hole in the casting on the back of the stove, right side as you look at it. It is operated by a little lever up top attatched to a chain. If you don't have these parts it would be fairly easy to fabricate them. Nice stove!

I'd see if you could get a wire cup brush for an angle grinder and clean it up and paint it with stove paint. It'll look, and work, like new.

You might need new gasket material on your doors.

Last edited by Take_a_knee; 07/14/13.
Joined: Dec 2009
Posts: 10,653
Campfire Outfitter
Offline
Campfire Outfitter
Joined: Dec 2009
Posts: 10,653
Looks like you have a Vigilant. In addition to a damper it should have a thermostat. Both are very important for a safe and efficient operation. I would not fire it without them working.

Vigilant


Last edited by roundoak; 07/14/13.

You're Welcome At My Fire Anytime



IC B3

Joined: Aug 2005
Posts: 7,262
Elf Offline OP
Campfire Tracker
OP Offline
Campfire Tracker
Joined: Aug 2005
Posts: 7,262
I have all the parts to it. It's a Vigilant model and it has the little flapper on the back. I'll clean it up and replace the gaskets as they are shot. I also have all the stove pipe to go with it. It will need to be able to damp down to hold a fire, this is my source of winter heat.

Joined: Dec 2009
Posts: 10,653
Campfire Outfitter
Offline
Campfire Outfitter
Joined: Dec 2009
Posts: 10,653
I should add...regardless of dampers and air control devices in wood stoves I always install a damper in the pipe for extra security.


You're Welcome At My Fire Anytime



Joined: Jun 2008
Posts: 2,805
C
Campfire Regular
Offline
Campfire Regular
C
Joined: Jun 2008
Posts: 2,805
light a fire in it and see if you can burn off the rust.


Clos

NRA Life Member


Joined: Aug 2006
Posts: 22,902
Campfire Ranger
Offline
Campfire Ranger
Joined: Aug 2006
Posts: 22,902
roundoak pegged it. Vigilant. Remove the inner backplate, free up the damper baffle, make sure the intake thermostat works and go to using it......The co. recommends NO pipe dampers be used. Check the bottom. They often burn out. Sometimes new stove cement is needed to seal cracks....

Joined: Aug 2006
Posts: 22,902
Campfire Ranger
Offline
Campfire Ranger
Joined: Aug 2006
Posts: 22,902
elf, another thing to check is for cracks in the back fireplate. Oftentimes they'll bend against the damper, and hamper operation..

Joined: Aug 2005
Posts: 15,676
Campfire Ranger
Offline
Campfire Ranger
Joined: Aug 2005
Posts: 15,676
I had that very stove in a house I used to live in on the Yukon River and believe me, you would be better off installing an in-pipe damper in it. As it came from the factory, the draft control was ill-fitted and would not shut off the air sufficiently and sheetmetal had to be used to take up the slop. Otherwise it would runaway. It also didn't hold fire very well as a result. An in-pipe damper would have mitigated those issues.


[Linked Image from i.pinimg.com]

Z
Joined: Sep 2009
Posts: 13,860
T
Campfire Outfitter
Offline
Campfire Outfitter
T
Joined: Sep 2009
Posts: 13,860
Originally Posted by Elf
I have all the parts to it. It's a Vigilant model and it has the little flapper on the back. I'll clean it up and replace the gaskets as they are shot. I also have all the stove pipe to go with it. It will need to be able to damp down to hold a fire, this is my source of winter heat.


Oh it'll damper down. My little Intrepid will hold a burn with pecan or oak for five hours, with coals enough to relight for another hour or two. That larger stove should add another hour or two to that at least. Burn what you have but try to keep some birch for your last loading and I'll bet it'll burn all night.

Joined: Jul 2004
Posts: 13,250
Campfire Outfitter
Offline
Campfire Outfitter
Joined: Jul 2004
Posts: 13,250
Originally Posted by Elf
I have all the parts to it. It's a Vigilant model and it has the little flapper on the back. I'll clean it up and replace the gaskets as they are shot. I also have all the stove pipe to go with it. It will need to be able to damp down to hold a fire, this is my source of winter heat.


Annie, I had a Vigilant. It's a great stove. The flap in the back is the thermostat. Mine would get to the point it would flap when the temperature in the room got to the right place. I'd have to keep adjusting it back and forth to keep the flapping noise down. I left my damper open all the time.

Joined: Apr 2002
Posts: 4,080
Q
Campfire Tracker
Offline
Campfire Tracker
Q
Joined: Apr 2002
Posts: 4,080
I had a stove with a "thermostat" and had more creosote than anyone would want. I now have a Pacific Energy with no damper in the pipe and it has burned very clean for 12 years. I only have one air inlet control. Built in 1977 that stove may other problems.

Qtip
Soli Deo Gloria!


"It's not a matter of legislating morality; it's a question of whose morality gets legislated"
Joined: Jan 2001
Posts: 59,126
R
Campfire Kahuna
Offline
Campfire Kahuna
R
Joined: Jan 2001
Posts: 59,126
Originally Posted by roundoak
I should add...regardless of dampers and air control devices in wood stoves I always install a damper in the pipe for extra security.
I had one in an earlier house with this same stove.. I'd never do it again.. All it can do is add potential problems.. But it would depend on the stove I guess.. I don't have a damper on this one and I've been running it every cold day since 1980..


Ex- USN (SS) '66-'69
Pro-Constitution.
LET'S GO BRANDON!!!
Page 1 of 2 1 2

Moderated by  RickBin 

Link Copied to Clipboard
AX24

541 members (12344mag, 01Foreman400, 007FJ, 10gaugemag, 1lessdog, 1234, 62 invisible), 2,320 guests, and 1,246 robots.
Key: Admin, Global Mod, Mod
Forum Statistics
Forums81
Topics1,190,659
Posts18,455,662
Members73,909
Most Online11,491
Jul 7th, 2023


 


Fish & Game Departments | Solunar Tables | Mission Statement | Privacy Policy | Contact Us | DMCA
Hunting | Fishing | Camping | Backpacking | Reloading | Campfire Forums | Gear Shop
Copyright © 2000-2024 24hourcampfire.com, Inc. All Rights Reserved.



Powered by UBB.threads™ PHP Forum Software 7.7.5
(Release build 20201027)
Responsive Width:

PHP: 7.3.33 Page Time: 0.102s Queries: 15 (0.003s) Memory: 0.8947 MB (Peak: 1.0463 MB) Data Comp: Zlib Server Time: 2024-04-19 18:05:15 UTC
Valid HTML 5 and Valid CSS