I've noticed our pressure tank/switch is kicking on/off constantly when any water is running.
It's in our basement where we spend much time in cold weather[why I'm noticing]
If showering or using water there is a noticeable pressure difference, surge of water then slows off a bit until the next surge.

Bad bladder?
If so, tank needs replaced?

Thanks


FJB & FJT
GB1

Joined: Jan 2001
Posts: 7,988
Campfire Outfitter
Offline
Campfire Outfitter
Joined: Jan 2001
Posts: 7,988
Either bad bladder or bad pressure switch...


Never underestimate your ability to overestimate your ability.
Joined: Mar 2007
Posts: 12,614
S
Campfire Outfitter
Offline
Campfire Outfitter
S
Joined: Mar 2007
Posts: 12,614
Had our pressure tank replaced 6 months ago suspecting bad bladder. Plumber (private 1 man business we use) said “Yep” then another “Yep” when he pulled the old one. Next was the well pump because it had been running so much. And wasn’t much to begin with. Not a real bad hit to the wallet….compared to no water when you’re in the shower, face full of soap, headed to the switch box and pump breaker in a robe barefoot.


“When Tyranny becomes Law, Rebellion becomes Duty”

Colossians 3:17 (New King James Version)
"And whatever you do in word or deed, do all in the name of the Lord Jesus, giving thanks to God the Father through Him."
Joined: Jan 2012
Posts: 26,456
R
Raeford Offline OP
Campfire Ranger
OP Offline
Campfire Ranger
R
Joined: Jan 2012
Posts: 26,456
Yes, I feel that this needs fixed asap if the pump is switching on/off as often as the switch!


FJB & FJT
Joined: Mar 2009
Posts: 1,845
V
Campfire Regular
Offline
Campfire Regular
V
Joined: Mar 2009
Posts: 1,845
Raeford,

Just like the other thread with a well pump/flow issue I think your pressure tank has a bad bladder. Your description on how your pump kicks off and on constantly is exactly what happens when there is little to no air in the tank to compress allowing storage of enough water in the system to prevent the pump from coming on as you describe.


Last edited by VaHunter; 11/22/21.
IC B2

Joined: Dec 2008
Posts: 6,907
T
Campfire Tracker
Offline
Campfire Tracker
T
Joined: Dec 2008
Posts: 6,907
Originally Posted by Raeford
Yes, I feel that this needs fixed asap if the pump is switching on/off as often as the switch!



Letting it go very long puts your well pump at risk.

Thankfully we have a handy-man guy I use for these issues. He seems like a decent enough plumber. And when I call, he responds asap because I pay on the spot. And he charges me a decent amount and I don't fuss. That little higher rate is gladly paid so that when I need him he responds.

Good luck.

Last edited by Tarkio; 11/22/21.

Montana MOFO
Joined: Dec 2008
Posts: 6,907
T
Campfire Tracker
Offline
Campfire Tracker
T
Joined: Dec 2008
Posts: 6,907
Originally Posted by VaHunter
Raeford,

Just like the other thread with a well pump/flow issue I think your pressure tank has a bad bladder. Your description on how your pump kicks off and on constantly is exactly what happens when there is little to no air in the tank to compress allowing storage of enough water in the system to prevent the pump from coming on as you describe.



+1

smile

Last edited by Tarkio; 11/22/21.

Montana MOFO
Joined: Mar 2006
Posts: 19,503
Campfire Ranger
Offline
Campfire Ranger
Joined: Mar 2006
Posts: 19,503
Classic pressure tank failure.


4 out of 5 Great Lakes prefer Michigan. smile
Joined: Oct 2021
Posts: 2,869
S
Campfire Regular
Offline
Campfire Regular
S
Joined: Oct 2021
Posts: 2,869
[Linked Image from media.giphy.com]

Joined: Aug 2004
Posts: 69,591
Campfire Kahuna
Offline
Campfire Kahuna
Joined: Aug 2004
Posts: 69,591
Check the air pressure in the tank.

Mine has a valve on top. It's 28 PSI.

Usually check and add air to the proper pressure a couple times a year.


Molɔ̀ːn Labé Skýla!
IC B3

Joined: Dec 2010
Posts: 14,408
R
Campfire Outfitter
Offline
Campfire Outfitter
R
Joined: Dec 2010
Posts: 14,408
you may just need to pressurize it. your pressure switch is set to turn on at a certain pressure and shut off at a certain (higher) pressure. theres lots of youtube vids on how to do this i'm sure. i've had to do this a few times. if it doesn't work then your pressure tank needs replaced.


My diploma is a DD214
Joined: Jan 2012
Posts: 26,456
R
Raeford Offline OP
Campfire Ranger
OP Offline
Campfire Ranger
R
Joined: Jan 2012
Posts: 26,456
Originally Posted by rockinbbar
Check the air pressure in the tank.

Mine has a valve on top. It's 28 PSI.

Usually check and add air to the proper pressure a couple times a year.


I'll check it this evening.
Thanks


FJB & FJT
Joined: May 2008
Posts: 25,492
A
Campfire Ranger
Offline
Campfire Ranger
A
Joined: May 2008
Posts: 25,492
Same exact thing happened to us earlier this year and it was a bad bladder. The guy that installed the original one when our house was built retired but his son Bill Jr took over and installed our new one. He said 10 years is about the average lifespan for a pressure tank.

Good luck…the holidays are a crappy time for that to happen.


�Politicians are the lowest form of life on earth. Liberal Democrats are the lowest form of politician.� �General George S. Patton, Jr.

---------------------------------------------------------
~Molɔ̀ːn Labé Skýla~
Joined: Jan 2012
Posts: 26,456
R
Raeford Offline OP
Campfire Ranger
OP Offline
Campfire Ranger
R
Joined: Jan 2012
Posts: 26,456
We're at 20 years with the tank, the original only lasted 2 years.


FJB & FJT
Joined: Jan 2006
Posts: 69,290
Campfire Kahuna
Online Content
Campfire Kahuna
Joined: Jan 2006
Posts: 69,290
Originally Posted by AcesNeights
Same exact thing happened to us earlier this year and it was a bad bladder. The guy that installed the original one when our house was built retired but his son Bill Jr took over and installed our new one. He said 10 years is about the average lifespan for a pressure tank.

Good luck…the holidays are a crappy time for that to happen.
I'm up to 26 years now on my pressure tank. I've only had to add air a couple times in those years.


“In a time of deceit telling the truth is a revolutionary act.”
― George Orwell

It's not over when you lose. It's over when you quit.
Joined: Dec 2010
Posts: 14,408
R
Campfire Outfitter
Offline
Campfire Outfitter
R
Joined: Dec 2010
Posts: 14,408
i'm at 10 years with my tank. first one lasted about 25 but needed recharged a lot. the one at my camp is 35 years old.


My diploma is a DD214
Joined: Feb 2005
Posts: 3,278
Campfire Tracker
Online Content
Campfire Tracker
Joined: Feb 2005
Posts: 3,278
Originally Posted by Raeford
Originally Posted by rockinbbar
Check the air pressure in the tank.

Mine has a valve on top. It's 28 PSI.

Usually check and add air to the proper pressure a couple times a year.


I'll check it this evening.
Thanks


The air pressure in the tank needs to be 2 p.s.i. lower than the pressure switch cutoff. The tank has to be empty of water to accurately adjust the air pressure. If you shut off the power to the pump and open a faucet or drain valve and there's still water in the tank after the line has drained, the bladder is waterlogged. You should replace the pressure switch when you replace the tank; they're cheap ($35-$40) but vital.


Haul ass, haul ass! - Pappy
Joined: Mar 2006
Posts: 19,503
Campfire Ranger
Offline
Campfire Ranger
Joined: Mar 2006
Posts: 19,503
Originally Posted by ShaunRyan
Originally Posted by Raeford
Originally Posted by rockinbbar
Check the air pressure in the tank.

Mine has a valve on top. It's 28 PSI.

Usually check and add air to the proper pressure a couple times a year.


I'll check it this evening.
Thanks


The air pressure in the tank needs to be 2 p.s.i. lower than the pressure switch cutoff. The tank has to be empty of water to accurately adjust the air pressure. If you shut off the power to the pump and open a faucet or drain valve and there's still water in the tank after the line has drained, the bladder is waterlogged. You should replace the pressure switch when you replace the tank; they're cheap ($35-$40) but vital.

I'm a plumber and this is the right way.^^^


4 out of 5 Great Lakes prefer Michigan. smile

Moderated by  RickBin 

Link Copied to Clipboard
AX24

281 members (16penny, 17CalFan, 10gaugemag, 1_deuce, 204guy, 1minute, 34 invisible), 2,307 guests, and 1,007 robots.
Key: Admin, Global Mod, Mod
Forum Statistics
Forums81
Topics1,191,171
Posts18,465,362
Members73,925
Most Online11,491
Jul 7th, 2023


 


Fish & Game Departments | Solunar Tables | Mission Statement | Privacy Policy | Contact Us | DMCA
Hunting | Fishing | Camping | Backpacking | Reloading | Campfire Forums | Gear Shop