I might weld once a year 2 days in a row. Not enough to justify a full time rod oven. My question, could I use a metal mail box with a light bulb to reach maybe 200 degrees for 2 days to dry the rods out? Looking for ideas, her oven is not an option. Neal

GB1

Joined: Apr 2010
Posts: 8,167
T
Campfire Outfitter
Offline
Campfire Outfitter
T
Joined: Apr 2010
Posts: 8,167
Is it a certified or otherwise very important weld? If not don’t worry about it. I never saw an oven in a rig truck when I was helpering or welding for an oilfield service, never saw one when I was iron working either.

If they’re rusty get some new rod. If not light them up.

Joined: Jul 2011
Posts: 1,800
M
Campfire Regular
Offline
Campfire Regular
M
Joined: Jul 2011
Posts: 1,800
What type of rods?

I would guess a cellulose electrode (6010, 7010, 6011). If so, store them in a dry place and you would be fine without any heat. In fact, for a cellulose rod, manufacturers do not recommend storing open containers in over 120F cabinets.

Low hydrogen rods are different. Once opened store at 275-300F. If damp and need to be dried heat to 750F for three hours or so and then store at 275-300F

Joined: Aug 2004
Posts: 69,599
Campfire Kahuna
Offline
Campfire Kahuna
Joined: Aug 2004
Posts: 69,599
I don't worry about a hot box for my 6011 rods. I use them most anyway.

You get into the low hydrogen rods, and you have to hot box them after you break the seal on the box.


Molɔ̀ːn Labé Skýla!
Joined: May 2016
Posts: 60,295
J
Campfire Kahuna
Online Happy
Campfire Kahuna
J
Joined: May 2016
Posts: 60,295
Havent found too much in the repair and maintenance field that would make me worry about hydrogen embrittlement very bad.


I am MAGA.
IC B2

Joined: Sep 2014
Posts: 21,767
Campfire Ranger
Offline
Campfire Ranger
Joined: Sep 2014
Posts: 21,767
Dad has airtight boxes for his 7018s.
They seem to work well for quite awhile.


Parents who say they have good kids..Usually don't!
Joined: Dec 2014
Posts: 9,095
F
Campfire Outfitter
Online Content
Campfire Outfitter
F
Joined: Dec 2014
Posts: 9,095
^^^yup^^^If your hot water heater is accessible, store your open containers on top, just enough heat to keep the rod warmer than the ambient temp will keep it dry. Very few of us are welding pressure piping on nuclear submarines.


Well this is a fine pickle we're in, should'a listened to Joe McCarthy and George Orwell I guess.
Joined: Feb 2019
Posts: 157
N
ndh19 Offline OP
Campfire Member
OP Offline
Campfire Member
N
Joined: Feb 2019
Posts: 157
Thanks for the info. Just welding for home and farm projects no certification needed other than my own pride. Neal

Joined: Jun 2019
Posts: 9,908
H
Campfire Outfitter
Offline
Campfire Outfitter
H
Joined: Jun 2019
Posts: 9,908
I use a piece of 4" PVC sewer pipe an inch or so longer than my rods with a cap glued onto one end and a cleanout plug on the other. No heat- - - -just an airtight environment to keep humidity out. I use mostly 7014- - - -it gives a flat, smooth bead like 7018, but it will run on AC without turning the heat way up and the slag falls away with just a tap of the hammer. 6011 makes a nasty looking bead!


Ignorance can be fixed. Stupid is forever!
Joined: May 2016
Posts: 60,295
J
Campfire Kahuna
Online Happy
Campfire Kahuna
J
Joined: May 2016
Posts: 60,295
Give us an idea what rods you are using.


I am MAGA.
IC B3

Joined: Aug 2004
Posts: 69,599
Campfire Kahuna
Offline
Campfire Kahuna
Joined: Aug 2004
Posts: 69,599
Originally Posted by Hotrod_Lincoln
6011 makes a nasty looking bead!

laugh

And I thought that was just my welding... LOL


Molɔ̀ːn Labé Skýla!
Joined: Feb 2019
Posts: 157
N
ndh19 Offline OP
Campfire Member
OP Offline
Campfire Member
N
Joined: Feb 2019
Posts: 157
Mostly 6011,6013, and 7018

Joined: Apr 2011
Posts: 151,108
Campfire Savant
Online Content
Campfire Savant
Joined: Apr 2011
Posts: 151,108
Originally Posted by Hotrod_Lincoln
I use a piece of 4" PVC sewer pipe an inch or so longer than my rods with a cap glued onto one end and a cleanout plug on the other. No heat- - - -just an airtight environment to keep humidity out. I use mostly 7014- - - -it gives a flat, smooth bead like 7018, but it will run on AC without turning the heat way up and the slag falls away with just a tap of the hammer. 6011 makes a nasty looking bead!


I use the PVC too

I use mostly 6011, like them better than 6010’s. I don’t understand the nasty weld comment. They make great looking welds.

Last edited by hanco; 02/06/23.
Joined: Feb 2019
Posts: 157
N
ndh19 Offline OP
Campfire Member
OP Offline
Campfire Member
N
Joined: Feb 2019
Posts: 157
I should also add I was taught by a old gruff Norwegian neighbor I was half scared of! I have his old Lincoln 225 tombstone buzz box AC only. Neal


Moderated by  RickBin 

Link Copied to Clipboard
AX24

597 members (17CalFan, 10gaugeman, 12344mag, 10ring1, 1337Fungi, 1941USMC, 52 invisible), 2,588 guests, and 1,108 robots.
Key: Admin, Global Mod, Mod
Forum Statistics
Forums81
Topics1,191,312
Posts18,468,241
Members73,928
Most Online11,491
Jul 7th, 2023


 


Fish & Game Departments | Solunar Tables | Mission Statement | Privacy Policy | Contact Us | DMCA
Hunting | Fishing | Camping | Backpacking | Reloading | Campfire Forums | Gear Shop
Copyright © 2000-2024 24hourcampfire.com, Inc. All Rights Reserved.



Powered by UBB.threads™ PHP Forum Software 7.7.5
(Release build 20201027)
Responsive Width:

PHP: 7.3.33 Page Time: 0.113s Queries: 14 (0.003s) Memory: 0.8498 MB (Peak: 0.9554 MB) Data Comp: Zlib Server Time: 2024-04-25 15:20:35 UTC
Valid HTML 5 and Valid CSS