Here’s the fix for you, that will save you guys a few thousand on time and material I’d bet. Just need to figure out what volume tank needs fabricated.

Instead of rerouting everything, I believe you could have a tank fabricated to put between the mixing valve and the intake manifold of the pump. Have them put a baffle on the intake side of the tank, to divert the water from just being a straight shot across the diameter of the tank, and into the 3.0 opening on the pump manifold.

Just picture a expansion tank being there.

Essentially what it would do is allow the pump to grab water out of the tank without the pressure drop immediately in the pipe at the mouth of the pump intake, as is right now. The volume of the tank would be where the pressure drop takes place.